MEP Calc

86+ calculation modules for mechanical services engineers. Heating, cooling, ventilation, fire protection and more, in your pocket.

iOS App 86+ Modules 8 Categories EN / TR
86+
Calculation Modules
8
Categories
2
Languages
PDF
Report Output

Category Screens

Specialist engineering calculations in every category

MEP Calc heating systems, 17 modules

Heating Systems

17 calculation modules. Circulation pump, pump head (Darcy-Weisbach), pump electrical power, pipe sizing and expansion vessel.

MEP Calc cooling systems, 10 modules

Cooling Systems

10 calculation modules. Chiller pump, cooling pump electrical power, pump head, pipe sizing and insulation.

MEP Calc ventilation, 11 modules

Ventilation (HVAC)

11 calculation modules. Duct sizing, equivalent duct diameter (rectangular to round), duct insulation, fan selection and distribution.

Specialist Calculation Modules

Deep calculators for fire protection, plumbing and psychrometrics

MEP Calc fire protection, 23 modules

Fire Protection

23 calculation modules. Sprinkler selection, NFPA 20 pump equipment, NFPA 13 test and drain valve, pump room ventilation, NPSH, diesel fuel tank and exhaust pipework.

MEP Calc plumbing, 8 modules

Plumbing

8 calculation modules. Booster set sizing, foul water pump, foul, cold and hot water pipe sizing, pool and irrigation calculations.

MEP Calc psychrometrics, load and airflow

HVAC Psychrometrics

Load and airflow calculation between two air states. Total, sensible and latent cooling load, with dry bulb, relative humidity and altitude inputs for precise analysis.

Sprinkler Selection Wizard

Choose your standard in four steps and let the app run the right calculation

MEP Calc sprinkler selection wizard, NFPA 13, FM Global and BS EN 12845

Three Standards, One Flow

Sprinkler design starts with one decision: which standard? The wizard takes you to the right calculations in four steps.

  • NFPA 13 — the American sprinkler standard, the most widely used
  • FM Global DS 8-9 — the FM Global industrial standard
  • BS EN 12845 — the European sprinkler standard (CMDA/CMSA/ESFR)

The next step shows the hazard class and the required inputs automatically.

All Categories

Heating — 18 modules
Cooling — 10 modules
Ventilation — 8 modules
Plumbing — 8 modules
Fire Protection — 21 modules
Compressed Air — 4 modules
Steam Systems — 5 modules
Natural Gas — 6 modules
Unit Converter — 6 types

Features

Everything you need on site and in the office

🔧

Pipe Sizing

Heating, cooling and plumbing pipe selection from DIN 2440 tables, with Hazen-Williams and Darcy-Weisbach support.

💨

Duct Sizing

Ventilation duct sizing with the Colebrook-White equation, and direct comparison of circular and rectangular ducts.

🔥

Fire Calculations

Sprinklers, FM200, foam suppression, NPSH and pump equipment, with NFPA 13, FM Global and BS EN 12845 support.

📈

Pump Selection

Heating and cooling pump flow, head and power consumption, plus expansion vessel sizing.

📄

PDF Reports

A professional PDF report for every calculation, in English or Turkish.

🔄

Unit Converter

Fast conversion between pressure, flow, length, temperature, power and energy units, across SI and IP systems.

In Use

86+ modules, 9 categories, one app — on the App Store

MEP Calc, 86+ modules in one app
MEP Calc, pick a category and start

How To Use It

Complete your calculation in three steps

Pick a Category

Choose your calculation category from the home screen: heating, cooling, ventilation, fire protection or another.

Enter the Values

Enter the engineering values the module needs, in either SI or IP units.

Get the Result

See the values on the instant results screen. Generate a PDF report or save it to your favourites.

Frequently Asked Questions

MEP Calc contains more than 86 engineering calculation modules, organised into 8 main categories: Heating (18 modules), Cooling (10), Ventilation/HVAC (8), Plumbing (8), Fire Protection (21), Compressed Air (4), Steam Systems (5) and Natural Gas (6). It also includes six types of unit converter.

MEP Calc uses DIN 2440 tables for heating and cooling pipe sizing — four separate tables, 18 friction resistance rows and 14 pipe diameter options for professional sizing. The Hazen-Williams and Darcy-Weisbach methods are supported in the fluid dynamics calculations.

Ventilation ductwork is sized with the Colebrook-White equation. This iterative equation calculates the friction factor and pressure loss precisely. You can compare circular and rectangular ducts and calculate equivalent diameter and area.

Yes — the fire protection category has 21 modules. It covers sprinkler calculations (NFPA 13, FM Global, BS EN 12845), FM200 (HFC-227ea) gaseous suppression, foam suppression (NFPA 11), NPSH, pump equipment, pump room ventilation, engine cooling circuits, diesel fuel tanks and more.

Yes. MEP Calc supports both SI (metric) and Imperial (IP) unit systems, and the unit system can be changed in every module. The formulas have separate calculation functions for SI and IP, so there is no intermediate conversion error. It also includes six independent unit converters: pressure, flow, length, temperature, power and energy.

MEP Calc is a free download from the App Store, and the core calculation modules are free to use. A Pro subscription is available for the fire protection calculations and advanced modules, with monthly and annual plans. It runs on iOS 17 and later.

Yes. A professional PDF report can be generated for every calculation module, in English or Turkish. The report sets out all input values, calculation parameters and results in detail, and can be shared by messaging, email or as a file.

Download Now

Get it from the App Store and take your engineering calculations to the next level.

View on the App Store → ← All apps