FM Global Articles

FM Global Property Loss Prevention Data Sheets translated into field practice, with the differences from NFPA set out explicitly.

DS 2-0DS 3-7DS 8-9DS 8-34DS 7-112
FM Global

FM Global DS 8-3: Rubber Tire Storage Summary

FM Global DS 8-3 summary: how tyres burn, stack arrangements, sprinkler and in-rack protection, drainage, outdoor tyre yards, NFPA 13 and EN 12845 differences.

Fatih Selvi
FM Global

FM Global DS 8-21: Roll Paper Storage Summary

FM Global DS 8-21 summary: paper grade and weight, on-end and horizontal rolls, arrays, banding and wrapping, sprinkler design, water absorption and NFPA 13.

Fatih Selvi
FM Global

FM Global DS 5-4: Transformers Summary

FM Global DS 5-4 summary: the transformer loss chain, condition monitoring, outdoor separation, fire barriers, oil containment, indoor vaults and water spray.

Fatih Selvi
FM Global

FM Global DS 4-5: Portable Extinguishers Summary

FM Global DS 4-5 summary: fire classes under NFPA 10 and EN 2, agent selection by hazard, placement, training, maintenance and NFPA 10 and EN 3 differences.

Fatih Selvi
FM Global

FM Global DS 4-2: Water Mist Systems Summary

FM Global DS 4-2 summary: water mist classes, how mist extinguishes, approval test limits, interlocks, and NFPA 750 and EN 14972 differences.

Fatih Selvi
FM Global

FM Global DS 2-0: High-Rise Sprinkler Design

High-rise sprinkler design under FM Global data sheets: DS 3-7 vertical zones (85 m) and no pumps in series, DS 3-11 pressure-reducing valve rules, DS 3-26 sprinkler selection and DS 2-8 riser details.

Fatih Selvi6 min
FM Global

FM Global DS 3-2: Fire Water Tank Heating Systems

Freeze protection for fire water tanks under FM Global DS 3-2: steam coils, electric immersion heaters, gas heaters, forced and gravity circulation, t...

Fatih Selvi6 min
FM Global

FM Global DS 3-7 Fire Pumps: A Field Guide

FM Global DS 3-7 fire protection pumps in practice: pump room location and construction, alarms, suction and discharge piping rules, relief valves, pu...

Fatih Selvi12 min
FM Global

FM Global DS 3-7: Variable Speed Fire Pump (VSP) Design

Variable speed fire pump design under FM Global DS 3-7: FM's cautious position (3.1.11) as a last resort for excess pressure, pressure-limiting control, FM Approved controllers, bypass and acceptance testing.

Fatih Selvi6 min
FM Global

FM Global DS 8-1: Mixed Commodity Storage Design

Mixed commodity storage under FM Global DS 8-1: the governing class rule, aisle separation, fire wall zoning and how the rules apply to e-commerce war...

Fatih Selvi6 min
FM Global

FM Global DS 8-34: Mini-Load ASRS Design

Mini-load ASRS fire protection under FM Global DS 8-34: angle-iron racking, conditions for ceiling-only protection, in-rack levels at a maximum vertical distance of 3.0 or 4.6 m, open-top versus closed-top containers, detection and robot shutdown.

Fatih Selvi6 min
FM Global

FM Global DS 8-34: Shuttle ASRS Fire Protection in Detail

Shuttle ASRS fire protection under FM Global DS 8-34: slatted-shelf racking, conditions for ceiling-only protection, in-rack levels set by vertical distance (not every tier), open-top containers, detection and robot shutdown.

Fatih Selvi7 min
FM Global

FM Global DS 8-34: Top-Loading and Crane-Based ASRS

Top-loading ASRS (TL-ASRS) protection under FM Global DS 8-34: robot holding areas, very early warning detection, ceiling sprinkler tables, final extinguishment and fire service access; DS 8-9 for crane-based pallet AS/RS.

Fatih Selvi6 min
FM Global

FM Global DS 8-9: CMSA and In-Rack Sprinkler Detail

FM DS 8-9 in-rack sprinkler (IRAS) rules: when they are needed (Figure 3), 70 °C quick-response and minimum K115 above 115 L/min, face sprinklers within 450 mm,...

Fatih Selvi7 min