Short, verifiable definitions of 109 core fire protection terms. The definitions follow the terminology of NFPA, EN and FM Global documents; the binding text is always the standard itself.
Sprinklers and heads
| Term | Definition |
|---|---|
| Sprinkler | An automatic water discharge device that opens with heat and distributes water in a defined pattern. |
| K-factor | The discharge coefficient of a sprinkler, relating flow to pressure in Q = K√P. |
| RTI | Response Time Index, the coefficient measuring how quickly a sprinkler responds to heat, in (m·s)^0.5. |
| Quick response (QR) | The fast-responding sprinkler class with an RTI of 50 or less. |
| Standard response | The class with an RTI above 80, preferred for storage ceiling applications. |
| Pendent sprinkler | A sprinkler hanging down from the pipe and discharging downwards. |
| Upright sprinkler | A sprinkler mounted above the pipe, facing upwards. |
| Sidewall sprinkler | A wall-mounted sprinkler discharging in a half-round pattern to one side. |
| Concealed sprinkler | A pendent sprinkler hidden behind a decorative cover plate that drops away with heat. |
| ESFR | Early Suppression Fast Response, a high K-factor quick-response sprinkler designed to suppress a storage fire from ceiling level. |
| CMSA | Control Mode Specific Application, a large-drop control mode sprinkler listed for defined storage arrangements. |
| CMDA | Control Mode Density Area, the classic control mode sprinkler designed by the density-area method. |
| In-rack sprinkler | An intermediate level sprinkler placed within racking, in the flue space. |
| Water shield | A metal disc of at least 0.075 m diameter protecting an in-rack sprinkler's thermal element from water above. |
| Baffle | A 200 mm by 150 mm shield placed between two sprinklers to prevent cold soldering. |
| Cold soldering | Where water from an operating sprinkler cools a neighbour and prevents it operating. |
| Glass bulb | The glass capsule that bursts as its liquid expands with heat, opening the sprinkler. |
| Fusible link | A mechanical sprinkler trigger held by solder that melts at a defined temperature. |
| Deflector | The plate that spreads water leaving a sprinkler into its designed pattern. |
| Spare sprinkler cabinet | A cabinet holding spare heads of every type and temperature used, plus the special wrench. |
System types
| Term | Definition |
|---|---|
| Wet pipe system | A sprinkler system whose pipework is permanently filled with pressurised water. |
| Dry pipe system | A system whose pipework is filled with compressed air and fed through a dry alarm valve. |
| Alternate system | A system operated wet in summer and dry in winter. |
| Pre-action system | A system where water enters the pipe only after independent detection operates. |
| Double interlock pre-action | A pre-action type requiring both detector operation and loss of pipe pressure. |
| Deluge system | A system with all heads open, where every head discharges when the valve opens. |
| Water spray system | A system distributing water through nozzles for equipment cooling and exposure protection. |
| Water mist system | A suppression system using very fine droplets for cooling and vapour dilution. |
| Wet alarm valve | The control valve in a wet system that senses flow and triggers the alarm. |
| Water motor gong | A mechanical alarm driven by water passing the valve, requiring no electricity. |
| Test and drain valve | The valve assembly at the end of a system for flow testing and draining. |
| Flow switch | A device that senses water flow in the pipe and generates an electrical alarm signal. |
| Tamper switch | A device monitoring that a valve stays open, signalling a fault when it closes. |
| Backflow preventer | A device preventing contamination of the potable supply by system water. |
Design and hydraulics
| Term | Definition |
|---|---|
| Design density | The water flow per unit of protected area, expressed in mm/min or gpm/ft². |
| Area of operation | The hydraulic calculation area covered by the sprinklers assumed to operate together. |
| Most remote area | The hydraulically most demanding sprinkler group, where the calculation starts. |
| Hazen-Williams equation | The relation calculating pipe friction loss using a C coefficient. |
| C factor | The Hazen-Williams constant representing internal pipe roughness. |
| Equivalent length | Expressing valve and fitting losses as an equivalent straight pipe length. |
| Velocity pressure | The dynamic component of total pressure arising from flow velocity. |
| Hydraulic balancing | Equalising the pressures of branches meeting at a node. |
| Hazard class | The LH, OH, HHP and HHS classification by fire load and rate of spread. |
| LH | Light Hazard, areas of low fire load such as offices, schools and hospital rooms. |
| OH1–OH4 | Ordinary Hazard, the four sub-classes of medium-risk production and commercial areas. |
| HHP | High Hazard Process, the class for high-risk production activities. |
| HHS | High Hazard Storage, the high-risk storage class, expressed as categories I to IV. |
| ST1–ST6 | The storage configuration types in EN 12845 (bulk, palletised, racked and so on). |
| Commodity class | In NFPA 13, Class I to IV and plastics grouping by the fire behaviour of material and packaging. |
| Flue space | The vertical clearance left between pallets in racking, through which heat and water pass. |
| Longitudinal flue | The gap between two back-to-back rack rows, required to be at least 0.15 m. |
| Transverse flue | The gap between side-by-side pallets, required to be at least 0.10 m. |
| Pallet stop | A mechanical stop preventing a pallet being pushed in and closing the flue. |
| Clearance | The distance between the top of the stored goods and the sprinkler deflector. |
Pumps and water supply
| Term | Definition |
|---|---|
| Fire pump | A listed centrifugal pump providing the system's required pressure and flow. |
| Jockey pump | An auxiliary pump maintaining system pressure by making up small leaks. |
| NPSHa | The net positive suction head the installation provides at the pump suction. |
| NPSHr | The net positive suction head the pump requires to avoid cavitation. |
| Cavitation | Bubble formation and collapse when suction pressure falls to vapour pressure, eroding the impeller. |
| Shut-off head | The pressure the pump produces at zero flow. |
| Overload point | Operation at 150% of rated flow, the NFPA 20 performance point. |
| Positive suction | Where the water source sits above the pump axis; the preferred arrangement. |
| Suction lift | Where the water source sits below the pump axis; restricted by NFPA 20. |
| Pressure maintenance | The control logic watching system pressure and starting the pump when it falls. |
| No automatic shutdown | The requirement that a fire pump be stopped manually rather than automatically. |
| Diesel fire pump | A pump with its own fuel tank and batteries, independent of mains electricity. |
| Water storage tank | A dedicated tank providing the volume required for the system's design duration. |
| Reduced capacity tank | A tank arrangement kept smaller by a controlled infill supply. |
| Suction pit | A recess at the tank floor allowing the pump to draw the last water. |
| Anti-vortex plate | A plate arrangement preventing air being drawn into the suction. |
Detection and alarm
| Term | Definition |
|---|---|
| Point smoke detector | A detector measuring smoke density at a single point. |
| Beam detector | A linear detector measuring attenuation of a beam between transmitter and receiver. |
| Aspirating detector | A highly sensitive system drawing air through pipes and analysing it centrally. |
| Heat detector | A detector operating on fixed temperature or rate of temperature rise. |
| Linear heat cable | A cable detector sensing heat at any point along its length. |
| Flame detector | A detector sensing UV or IR radiation to identify flame very quickly. |
| Addressable system | A fire detection architecture where each device is identified by its own address. |
| Conventional system | An architecture grouping devices by zone, without individual addresses. |
| Fire alarm panel | The central control unit monitoring detection devices and managing the alarm. |
| Sounder | A siren or loudspeaker giving audible warning in a fire. |
| Visual alarm device | A flashing warning for noisy areas or where users may be hearing impaired. |
| Alarm receiving centre | A remote centre where alarm signals are continuously monitored. |
| Cross-zoning | Logic requiring confirmation from two separate detectors to reduce false alarms. |
Other suppression systems
| Term | Definition |
|---|---|
| Clean agent | A non-conductive gaseous agent leaving no residue after discharge. |
| Inert gas | Argon, nitrogen or a mixture that suppresses by diluting oxygen. |
| Hold time | The period the agent concentration is retained in the enclosure after discharge. |
| Door fan test | A test measuring enclosure tightness to verify the hold time. |
| Pressure relief damper | A damper venting the overpressure produced during agent discharge. |
| NOAEL | The highest agent concentration at which no adverse physiological effect is observed. |
| AFFF | Aqueous film-forming foam concentrate used on hydrocarbon fires. |
| AR-AFFF | An alcohol-resistant AFFF usable on polar solvents as well. |
| F3 foam | Fluorine-free foam concentrate, the PFAS-free generation of product. |
| Foam proportioner | A device blending foam concentrate into water at the correct ratio. |
| Kitchen hood system | A wet chemical suppression system for fryer and range cooking oil fires. |
| Hose reel cabinet | First-response equipment housing a hose reel or lay-flat hose. |
| Fire hydrant | An external water take-off point fed from the main, for fire brigade connection. |
| Fire brigade connection | An external inlet allowing a fire appliance to pump into the system. |
Inspection, testing and maintenance
| Term | Definition |
|---|---|
| Main drain test | A flow test through the main drain checking the condition of the water supply. |
| Alarm test | A weekly test verifying operation of the alarm valve and water motor gong. |
| Inspector's test valve | A test valve at the most remote point simulating the flow of one sprinkler. |
| Annual flow test | An annual test verifying the pump's flow-pressure curve on site. |
| Dry system trip test | A test measuring the opening time of the dry alarm valve. |
| Obstruction investigation | An examination for sediment, corrosion and blockage inside the pipework. |
| Microbiologically influenced corrosion | Pitting corrosion of the pipe wall caused by bacterial activity (MIC). |
| Acceptance test | The set of tests verifying the system matches the design before handover. |
| Hydrostatic test | Holding the pipework under water pressure above its design pressure. |
| Flushing | Clearing foreign material from the pipework by flow before commissioning. |
| Impairment | Temporarily taking the system out of service for maintenance, with compensating measures. |
| Hot work permit | A controlled permit system for spark-producing work such as welding and cutting. |
How to use this page
This page is a quick reference list. For a detailed reading of what a term means in design, see the glossary articles; to see the difference between two standards, see the comparison articles.
Frequently Asked Questions
Are the definitions on this page binding?
No. They are summaries following NFPA, EN and FM Global terminology; the binding text is always the relevant standard itself.
What is the difference between K-factor and design density?
The K-factor is the discharge coefficient of a single sprinkler. Design density is the flow per unit of protected area; together they determine the sprinkler selection.
What is the difference between control mode and suppression mode?
Control mode limits the fire and cools its surroundings, leaving extinguishment to the fire brigade. Suppression mode (ESFR) aims to suppress the fire directly from ceiling level.

SprinkCalc — Fire Sprinkler Design Across Three Standards
SprinkCalc covers hazard classification, design density and area, K-factor selection, water demand and hydraulic calculations for NFPA 13, FM Global and BS EN 12845 in a single iOS app, and exports a professional PDF report.
Download SprinkCalc on the App Store
MEP Calc — 86+ Engineering Calculators
MEP Calc bundles 86+ engineering modules in one iOS app: 21 fire calculations plus heating, cooling, HVAC, plumbing, steam and natural gas.
Download MEP Calc on the App StoreNFPA 13 (2025) · NFPA 20 (2025) · NFPA 25 · NFPA 15 · NFPA 72 · NFPA 855 · BS EN 12845:2015+A1:2019 · EN 54 series · FM Global Data Sheets. Definitions are for information only; the binding text is the standard itself.