Turkey's large airports reach annual capacities of 90, 41 and 39 million passengers. At the largest, the terminal covers 1.4 million m², there are 230 passenger boarding bridges, and about 800,000 L of Jet A-1 is held on the apron. At this scale NFPA 415 brings boarding bridge roof protection, apron drainage, a 3% AFFF foam system and atrium smoke control to the table at the same time. The hardest part on these projects is planning from the start that these systems must work as an integrated whole, not independently.
Terminal Hazards
- Atrium: 30–40 m high, with an unprotected steel roof
- Baggage conveyors: 15 km long; the rubber belts add fire load
- Duty-free shops: High fire load from alcohol, perfume and cosmetics
- Occupant load: 40,000 people at peak hour; the evacuation scenario is critical
- Jet A-1 hydrant system: Pressurized line beneath the apron
NFPA 415 and Passenger Boarding Bridges
- Passenger boarding bridge: Protection of the roof and tunnel is mandatory
- Sprinklers: 5.7 L/min/m² density inside the tunnel
- Egress: Reverse-direction exit to the apron
- Shell: Glass-fiber panels
- Proximity: 15 m to the aircraft; fuel fire risk
Apron Drainage
- Fuel spill: 800 L/min Jet A-1 scenario flow rate
- Drainage slope: 1% for proper surface runoff
- Oil separator: API 421 criteria
- Foam monitor: 1,900 L/min capacity
- Aircraft rescue and firefighting (ARFF): 3-minute response time
Atrium Smoke Control
- NFPA 92: Reference standard for smoke control
- CFD modeling: Scenario simulation with FDS 6
- Exhaust fans: 10–15 air changes per hour
- Makeup air: Natural or mechanical inlets
- Smoke-free height: The smoke layer must stay at least 1.8 m above the egress path
Turkey Airports
- Largest airport: Annual capacity of 90 million passengers
- Second-largest hub: 41 million passengers
- Tourism airport: 39 million passengers; tourism-driven seasonal peaks
- Another large airport: 17 million passengers
- Largest terminal: Opened with a 1.4 million m² terminal

MEP Calc — 110+ Engineering Calculators
MEP Calc bundles 110+ engineering modules in one iOS app: 21 fire calculations (sprinkler, fire pump, FM-200 clean agent) plus heating, cooling, HVAC, plumbing, steam and natural gas. Download it on the App Store.
Download MEP Calc on the App Store
SprinkCalc — Fire Sprinkler Design Across Three Standards
SprinkCalc covers hazard classification, design density and area, K-factor selection, water demand and hydraulic calculations for NFPA 13, FM Global and BS EN 12845 in a single iOS app, and exports a professional PDF report. One of the few tools that unifies all three major fire protection standards.
Download SprinkCalc on the App StoreNFPA 415, NFPA 92, ICAO Annex 14, FAA AC 150/5210. NFPA 415 Aircraft Fueling Ramp Drainage and Loading Walkways.